The model CCX Loadcell is heavy duty weighing applications, inclubing hoppers, tanks, silos and high capacity scales.
- Insensitive to side load
- Double convex type
- Robust high capacity design
Load cell
The model CCX Loadcell is heavy duty weighing applications, inclubing hoppers, tanks, silos and high capacity scales.
| Specifications | Accuracy |
|---|---|
| Rated capacity(R.C) | 5tf, 10tf, 20tf, 30tf, 50tf, 100tf, 200tf, 300tf, 500tf |
| Rated output(R.O) | 1.5 mV/V±0.5% |
| Nonlinearity | 0.1% of R.O. |
| Hysteresis | 0.1% of R.O. |
| Repeatability | 0.05% of R.O. |
| Creep(20min) | 0.05% of R.O./20min |
| Zero balance | 1% R.O. |
| Temperature effect, on rated output | 0.03% of LOAD/10℃ |
| Temperature effect, on zero balance | 0.03% of R.O./10℃ |
| Temperature range, compensated | -10~60℃ |
| Temperature range, safe | -20~80℃ |
| Terminal resistance input | 350 ±5Ω |
| Terminal resistance output | 350 ±5Ω |
| Insulation resistance | 2000MΩ |
| Excitation recommended | 10V DC |
| Safe overload | 150% R.C |
| Cable length | Φ7±, 4coreshied, 3m |